APEX ATLAS
ENGINEERING & QUALITY ASSURANCE

Engineered for Demanding Operating Conditions

Verified Materials. Documented Performance.

Systems and materials are specified against project requirements, operating conditions and applicable technical standards.

01

STRUCTURAL INTEGRITY & REINFORCEMENT

Structural systems are engineered according to site conditions, design loads, installation requirements and the approved project specification.

  • Reinforced structural configurations
  • Site-specific load assessment
  • Foundation and anchoring coordination
  • Material and reinforcement selection
  • Engineering calculations and technical submittals
Standard: PROJECT-SPECIFIC STRUCTURAL DESIGN CRITERIA
02

BALLISTIC & FORCED-ENTRY RESISTANCE

Ballistic and forced-entry protection is configured using supplier-tested doors, glazing, panels and complete assemblies selected according to the required threat level and approved project specification.

  • Ballistic-resistant wall and panel configurations
  • Security doors selected to the required resistance class
  • Bullet-resistant glazing options
  • Integrated frames, fixings and locking systems
  • Test documentation available for specified assemblies
Standard: EN 1522 / EN 1627 / EN 1063 / NIJ 0108.01 APPLICABLE TO SELECTED TESTED ASSEMBLIES
03

FIRE-RESISTANT DOORS & OPENING PROTECTION

Fire-resistant metal and glazed door assemblies are selected according to the required fire rating, opening configuration and approved project specification.

  • Fire-rated metal and glazed door options
  • Available EI ratings from 30 to 180 minutes
  • Thermal-insulation options for selected assemblies
  • Integration with security and protective-door requirements
  • Certification documentation available for specified products
Standard: EI30–EI180 APPLICABLE TO SELECTED CERTIFIED DOOR ASSEMBLIES
04

ACCESS CONTROL & SECURITY INTEGRATION

Locking, access-control and monitoring options are coordinated with the selected protective structure and the client’s security requirements. Equipment and integration scope are confirmed for each project.

  • Customised locking and access-control options
  • Multi-point locking for selected protective doors
  • Provision for CCTV equipment and security sensors
  • Intercom and communications options
  • Coordination with the facility’s security systems
Standard: PROJECT-SPECIFIC EQUIPMENT & INTEGRATION REQUIREMENTS
05

BACKUP POWER & OPERATIONAL CONTINUITY

Backup power options support essential shelter equipment during interruptions to the normal electricity supply. Capacity and operating duration are selected according to equipment loads, available energy storage and project requirements.

  • Battery and UPS options for essential equipment
  • Generator connection and backup generation options
  • Solar and battery configurations for selected systems
  • Emergency lighting and electrical distribution
  • Operating duration assessed against the specified equipment load
Standard: PROJECT-SPECIFIC ELECTRICAL & BACKUP-POWER REQUIREMENTS
06

GRP & GRV WATER & INFRASTRUCTURE PIPING

Corrosion-resistant composite pipes and fittings for water, wastewater, stormwater, desalination, and industrial utility networks. Pipe construction and jointing are selected according to the fluid, design pressure, temperature, and installation requirements.

  • Continuous-wound diameter range: DN 80–4,000 mm
  • Selected helical-wound options: DN 25–1,200 mm
  • Pressure ratings up to 32 bar, depending on configuration
  • Temperature capability up to 85°C, subject to service conditions
  • Standard GRP stiffness classes: SN 2,500 / 5,000 / 10,000 Pa
  • Published standard pipe lengths: 6–12 m
  • Polyester and vinyl-ester resin options
  • Restrained and non-restrained jointing configurations
  • Coupler, flanged, and laminated joint options
  • Buried and above-ground installation options
Standard: APPLICABLE STANDARDS CONFIRMED PER SELECTED SYSTEM
07

SPECIALIST JACKING & INDUSTRIAL PIPING

Specialist composite systems for micro tunnelling, utility crossings and demanding industrial or marine services. Jacking pipes and heavy-wall pipes are separate product families, each selected against its installation loads and operating requirements.

  • Jacking stiffness classes: SN 20,000–1,000,000 Pa
  • Jacking pressure ratings up to 10 bar
  • Project-specific jacking loads, diameters, and pipe lengths
  • Factory-built grouting ports for jacking systems
  • Hybrid composite or stainless-steel sleeve coupling options
  • Heavy-wall diameter range: DN 25–1,500 mm
  • Heavy-wall pressure ratings up to 14 bar
  • Heavy-wall temperature capability up to 65°C
  • Conductive heavy-wall configurations available
Standard: PERFORMANCE & APPROVALS CONFIRMED PER SELECTED PRODUCT

Need detailed technical specifications for your project?
Discuss your requirements with our engineering team.

REQUEST TECHNICAL CONSULTATION